10kV Arresters diameters 28mm 30mm zinc oxide varistors,repetitive charge transfer Qrs (C) is 0.3C,guaranted 2ms test current (A) is 150A,4/10µs high current test (kA)is 65kA. suggested rated voltage (kV)is 3.6kV or 4.5kV

Product Details

The large number of metal oxide varistor manufacturing process, polymer-housed surge arresters test, D28H29 And D28H35 metal oxide varistors BLOCKS we offered are in reliable quality, with worldwide availability and technical support, thus it has a clear competitive advantage in the global market. Our cultural concept system is composed of core values, corporate mission and vision, which embodies our thoughts, pursuit and responsibilities. We aim to continuously enhance the value of relevant stakeholders such as customers, investors, partners and employees.

10kV Arresters which use diameters 28mm or 30mm zinc oxide varistors.

type D28H23.5 D28H29 D30H23.5 D30H29
AC system AC AC AC AC
suggested rated voltage (kV) 3.6 4.5 3.6 4.5
MCOV (kV) 3.1 3.8 3.1 3.8
diameter (mm) 28±0.7 28±0.7 30±0.7 30±0.7
height (mm) 23.5±0.3 29±0.3 23.5±0.3 29±0.3
DC U1mA (kV) 5.52±0.3 6.82±0.35 5.52±0.3 6.82±0.35
IL at 75% of U1mA
(µA)
≤ 10≤ 10≤ 10≤ 10
Ures (kV) 9.7±0.5 12.0±0.6 9.5±0.5 11.7±0.6
typical Ures / U1mA 1.75 1.75 1.72 1.72
repetitive charge transfer Qrs (C) 0.3 0.3 0.3 0.3
guaranted 2ms test current (A) 150 150 150 150
max 2ms test current (A) 150 150 200 200
4/10µs high current test (kA) 65 65 65 65
nominal discharge current In (kA) 5 5 5 5
accelerated ageing test 115℃
0.9*U1mA/√2
Kct ≤ 1.0
115℃
0.9*U1mA/√2
Kct ≤ 1.0
115℃
0.9*U1mA/√2
Kct ≤ 1.0
115℃
0.9*U1mA/√2
Kct ≤ 1.0


type D28H23.5 D28H29 D30H23.5 D30H29
AC system AC AC AC AC
suggested rated voltage (kV) 3.6 4.5 3.6 4.5
MCOV (kV) 3.1 3.8 3.1 3.8
diameter (mm) 28±0.7 28±0.7 30±0.7 30±0.7
height (mm) 23.5±0.3 29±0.3 23.5±0.3 29±0.3
DC U1mA (kV) 5.52±0.3 6.82±0.35 5.52±0.3 6.82±0.35
IL at   75% of U1mA
    (µA)
≤ 10≤ 10≤ 10≤ 10
Ures   (kV) 9.7±0.5 12.0±0.6 9.5±0.5 11.7±0.6
typical Ures / U1mA 1.75 1.75 1.72 1.72
repetitive charge transfer Qrs (C)  0.3 0.3 0.3 0.3
guaranted 2ms test current (A) 150 150 150 150
max 2ms test current (A) 150 150 200 200
4/10µs high current test (kA) 65 65 65 65
nominal discharge current In (kA) 5 5 5 5
accelerated ageing test 115℃
 0.9*U1mA/√2
    Kct ≤ 1.0

115℃ 

0.9*U1mA/√2

    Kct ≤ 1.0
115℃
0.9*U1mA/√2
    Kct ≤ 1.0
115℃
 0.9*U1mA/√2
    Kct ≤ 1.0


Our company provides the quality service from start to end, we have many experience in the Surge Device Protection M40fa990A Surge Suppressor Surge Protection Device Types field, we listen to the client's need and find the most proper solution for it. What we provide for our employees is not just a job, but a career, a stage where they can give full play to their strengths, talents and creativity. We have established deep friendships and good cooperative relationships with our customers.
Hot Tags: 10kv arresters diameters 28mm 30mm zinc oxide varistors China, suppliers, manufacturer, factory, distribution class, high voltage, high performance, medium voltage, test, size, best, IEC 60099-4 2014, distribution networks, best dead-front arresters, metal oxide varistor testing pdf, metal oxide varistorsd, D30 High Performance MOVSd, best high gradient varistors, best railway surge arresters