Lightning Protector SPD 60ka Electrical Surge Protector Power Lightning Surge Arrester

Lightning Protector SPD 60ka Electrical Surge Protector Power Lightning Surge Arrester

Repetitive charge transfer Qrs (C) is 0.5C,guaranted 2ms test current (A) is 400A,4/10µs high current test (kA)is 100kA. suggested rated voltage (kV)is 3.2kV or 5.5kV

Product Details

We are committed to becoming a trusted D30 High Performance MOVSd, D28 High performance AC metal oxide varistors test, D30 High Performance MOVS solution provider. Our products are wide-ranging, complete in size and in accordance with international and national standards, and can be adapted to different customer working conditions. With many years of industry experience, we provide customers with a series of comprehensive services from design, R&D, manufacturing and after-sales. Over the years, we rely on the innovation concept of constantly improving and surpassing to continuously improve the value of our products. We provide all our customers with first-rate technology, a mature and fast service, that is our everlasting promise!


MOV Blocks diameter from 38mm to 40mm.


AC systemACACACACACAC
typeD38H20.7D38H31D38H34.5D40H20.7D40H31D40H34.5
suggested rated voltage (kV)3.24.95.43.34.95.5
MCOV (kV)2.84.14.62.84.24.6
diameter (mm)38.5±0.738.5±0.738.5±0.740±0.740±0.740±0.7
height (mm)23.5±0.329±0.335±0.323.5±0.329±0.335±0.3
DC U1mA (kV)4.85±0.37.3±0.458.1±0.54.85±0.37.3±0.458.1±0.5
IL at 75% of U1mA(µA)≤ 15≤ 15≤ 15≤ 15≤ 15≤ 15
Ures(kV)8.6±0.512.9±0.814.35±0.88.5±0.512.8±0.814.2±0.8
typical Ures / U1mA1.771.771.771.751.751.75
repetitive charge transfer Qrs (C)0.50.50.50.50.50.5
guaranted 2ms test current (A)400400400400400400
max 2ms test current (A)450450450500500500
4/10µs high current test (kA)100100100100100100
nominal discharge current In (kA)101010101010
accelerated ageing test115℃ 0.9*U1mA/√2
Kct ≤ 1.0
115℃0.9*U1mA/√2
Kct ≤ 1.0
115℃ 0.9*U1mA/√2
Kct ≤ 1.0
115℃ 0.9*U1mA/√2
Kct ≤ 1.0
115℃0.9*U1mA/√ Kct ≤ 1.0115℃0.9*U1mA/√2
Kct ≤ 1.0


MOV Blocks diameter from 38mm to 40mm.

AC systemACACACACACAC
typeD38H20.7D38H31D38H34.5D40H20.7D40H31D40H34.5
suggested rated voltage (kV)3.24.95.43.34.95.5
MCOV (kV)2.84.14.62.84.24.6
diameter (mm)38.5±0.738.5±0.738.5±0.740±0.740±0.740±0.7
height (mm)23.5±0.329±0.335±0.323.5±0.329±0.335±0.3
DC U1mA (kV)4.85±0.37.3±0.458.1±0.54.85±0.37.3±0.458.1±0.5
IL at   75% of            U1mA(µA)≤ 15≤ 15≤ 15≤ 15≤ 15≤ 15
Ures(kV)8.6±0.512.9±0.814.35±0.88.5±0.512.8±0.814.2±0.8
typical Ures / U1mA1.771.771.771.751.751.75
repetitive charge transfer Qrs (C) 0.50.50.50.50.50.5
guaranted 2ms test current (A)400400400400400400
max 2ms test current (A)450450450500500500
4/10µs high current test (kA)100100100100100100
nominal discharge current In (kA)101010101010
accelerated ageing test115℃ 0.9*U1mA/√2
 Kct ≤ 1.0
115℃0.9*U1mA/√2
 Kct ≤ 1.0
115℃ 0.9*U1mA/√2
 Kct ≤ 1.0
115℃ 0.9*U1mA/√2
 Kct ≤ 1.0
115℃0.9*U1mA/√ Kct ≤ 1.0115℃0.9*U1mA/√2
 Kct ≤ 1.0


We adhere to the after-sales return visit, which has accumulated important data for the company and is convenient for leaders to make decisions and develop new Lightning Protector SPD 60ka Electrical Surge Protector Power Lightning Surge Arrester. We have professional technical personnel and research and development capabilities, and can customize various products according to customer requirements. Constantly striving for self-improvement, pursuing excellence and creating the future together is our management philosophy. We will give full play to our own advantages, continue to improve and provide quality products, excellent services to serve users and the society.
Hot Tags: mov blocks diameter from 28mm to 42mm China, suppliers, manufacturer, factory, distribution class, high voltage, high performance, medium voltage, test, size, best, IEC 60099-4 2014, distribution networks, Zinc oxide lightning arrester, Nominal Discharge Current 5kA MOVs, surge divider, best dead-front arresters, Nominal Discharge Current 5kA MOVs size, D28 High performance AC metal oxide varistors